Polyvinylidene Fluoride (PVDF) Membrane with extended life and superior chemical resistance designed in a wide range of industrial and electro-coat application, Ultrafiltration Spiral elements provide greater resistance to fouling by colloidal particles and oily contamination. The Polyvinylidene Flouride (PVDF) membrane provides excellent chemical and temperature resistance under a variety of process conditions.
UF Spiral Elements are designed to fit virtually all applications and housings. This includes the smaller elements commonly used from the laboratory or small volume applications such as the 1812 to 2521 sizes. There larger scale production scale elements are available to fit virtual all available housing design from the 4” 40281 to the 8” 8340 sizes. Their diameters, outer construction, lengths, and product water tube configurations fit competitive housings.
Applications :
Anodic/Cathodic Paint
Select Water Borne Paints
Waste Water Recycle
Alkaline Cleaner Recovery
PVA Recovery
Materials of Construction: | |
Membrane | : Polyvinylidene Fluoride |
Backing Material | : Polyester |
Permeate Tube | : Polyvinyl Chloride (PVC) |
Seal Carrier | : ABS Plastic |
Brine Seal | : EPDM |
Operating Conditions: | |
Maximum Inlet Pressure | :60 psi (4.1 bar) |
Typical Inlet Pressure |
:40-60 psi (2.7-4.1 bar) (application specific) |
Maximum Operating Temperature | :122°F (50°C) |
pH Range, continuous | :2-10 |
pH Range, short-term cleaning | :2-11.5 @122°F (50°C) |
Dimensions :
PART NUMBER | DIAMETER | OVERALL LENGTH | AREA | DESCRIPTION | ||||||||
(in) | (cm) | (in) | (cm) | (ft2) | (m2) | |||||||
EP1812-BS01-TB |
1.8 |
4.6 |
12 |
30.5 |
3.4 |
0.3 |
Taped element for a PAF PMC-1812-HSG housing |
|||||
EP2514-BS01-T2 |
2.41 |
6.1 |
14 |
35.6 |
5.5 |
0.5 |
Taped element for a PAF2R2514 series housing |
|||||
EP2521-BS01-H2 |
2.41 |
6.1 |
21 |
53.3 |
10.9 |
1 |
Taped element for a PAF2R2521 series housing |
|||||
EP40281BS01-H4 |
3.88 |
9.9 |
28 |
71.1 |
47 |
4.4 |
Sealed element for PAF2R4028 & 1VUF30 series PVC housing |
|||||
EP4033-BS01-H4 |
3.88 |
9.9 |
33 |
83.8 |
57 |
5.3 |
Sealed element for PAF 2R4033 series PVC housing /Koch 4” retrofit |
|||||
EP4040-BS01-HL |
3.88 |
9.9 |
40 |
101.6 |
75 |
7 |
Netted element for PAF1VUF40 series PVC housing or SS housing |
|||||
EP4040-BS02-H4 |
3.88 |
9.9 |
40 |
101.6 |
75 |
7 |
Sealed element for Osmonics 4 SS housing " |
|||||
EP4040-BS03-H4 |
3.88 |
9.9 |
40 |
101.6 |
70 |
6.5 |
Sealed element for Osmonics 4 SS housing (Reinforced Construction) " |
|||||
EP4040-BS07-H4 |
3.88 |
9.9 |
40 |
101.6 |
70 |
6.5 |
Sealed element for PAF 2R4040 series PVC housing |
|||||
EP4040-BS01-H4 |
3.88 |
9.9 |
40 |
101.6 |
72 |
6.7 |
Sealed element for PAF 2R40SP series PVC housing (Filmtec Style) |
|||||
EP40451BS02-H4 |
3.88 |
9.9 |
45 |
114.3 |
81 |
7.5 |
Sealed element for PAF 2R4045 & 1VUF50 series PVC housing |
|||||
EP5640-BS01-H5 |
5.45 |
13.8 |
40 |
101.6 |
153 |
14.2 |
Sealed element for 6 PAF 2VUF60 series PVC housing " |
|||||
EP5640-BS01-HL |
5.9 |
15 |
40 |
101.6 |
153 |
14.2 |
Netted element for 6 PAF 2VUF60 series PVC housing /Synder 6" retrofit " |
|||||
EP56475BS01-H5 |
5.45 |
13.8 |
47.5 |
120.7 |
180 |
16.7 |
Sealed element for Synder 6 housing " |
|||||
EP6439-BS01-HL |
6.3 |
16 |
39 |
99.1 |
162 |
15.1 |
Netted element for Koch 6 PVC housing " |
|||||
EP7637-BS02-H7 |
7.48 |
19 |
37 |
94 |
218 |
20.3 |
Sealed element for Koch 8 PVC housing " |
|||||
EP7640-BS01-H7 |
7.28 |
18.5 |
40 |
101.6 |
278 |
25.8 |
Sealed for new style PAF 2VUF80 series PVC or SS housing |
|||||
EP7640-BS02-H7 |
7.28 |
18.5 |
40 |
101.6 |
278 |
25.8 |
Sealed for older PAF 2VUF80 series PVC housing |
|||||
EP7640-BS03-H7 |
7.48 |
19 |
40 |
101.6 |
278 |
25.8 |
Sealed element for PAF 2VUF80 series PVC housing -with double seal ATD |
EP7640-BS01-HL |
7.6 |
19.3 |
40 |
101.6 |
278 |
25.8 |
Netted element for 8 PAF 2VUF80 series PVC housing Synder 8" retrofit " |
EP76475-BS01-H7 |
7.48 |
19 |
47.5 |
120.7 |
317 |
29.5 |
Sealed element for 8 Synder PVC /SS housing " |
EP7940-BS03-HL |
7.9 |
20.1 |
40 |
101.6 |
333 |
30.9 |
Netted element for Osmonics 8 SS40 housing " |
EP8040-BS07-H8 |
7.9 |
20.1 |
40 |
101.6 |
341 |
31.7 |
Sealed element for Hydranautics 8 housing " |
EP8340-BS01-H8 |
8.27 |
21 |
40 |
101.6 |
389 |
36.1 |
Sealed element for Osmonics 8 SS10 housing " |
EP8340-BS14-H8 |
7.9 |
20.1 |
40 |
101.6 |
344 |
31.7 |
Sealed element for Osmonics 8 SS40 housing " |
EP4040-BS03-H4 UF Membrane
EP7640-BS01-H7 UF Membrane
EP Ultrafi ltration Spiral Elements
EP5640-BS01-H5 UF Membrane
EP76475-BS01-H7 UF Membrane
FAST cell
EP7637-BS02-H7 UF Membrane
EP8040-BS14-H8 UF Membrane
UF Cleaning Procedures